44
© 2014 AEM Performance Electronics
7100-XXXX-62
7101-XXXX-63
Function
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. Normally
used as USB Logging Request input. *Pin
not populated in 30-3805 Univ ersal V8
Base harness.
12 bit A/D, 100K pullup to 5V
0–5V analog signal. Use +5V Out pins as
power supply and Sensor Ground pins as
the low ref erence. Do not connect signals
ref erenced to +12V as this can
permanently damage the ECU. Normally
used as Charge Out Pressure input. *Pin
not populated in 30-3805 Univ ersal V8
Base harness.
No pullup. Will work with TTL signals.
Input can be assigned to dif f erent pins.
See Setup Wizard page Input Function
Assignments for input mapping options.
No pullup. Will work with TTL signals.
See ClutchSwitch 1-axis table f or setup
options. Input can be assigned to
dif f erent pins. See Setup Wizard page
Input Function Assignments f or input
mapping options.
Connect directly to battery ground.
Connect directly to battery ground.
Dedicated High Speed CAN Transceiv er
Dedicated High Speed CAN Transceiv er
Engine Protect
Warning Out
Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.
Activ ates if any of the f ollowing f lags are
true: OilPressProtectOut,
LeanProtectOut, CoolantProtect. Output
can be assigned to other f unctions. See
Setup Wizard page LowSide Assignment
Tables f or additional options.
Lowside switch, 4A max with internal
f ly back diode. Inductiv e load should NOT
hav e f ull time power.
Normally used as Spare GPO1 output.
*Pin not populated in 30-3805 Univ ersal
V8 Base harness.
Virtual Ground signal. Connect to pin 5 of
Bosch UEGO sensor.
Nernst Voltage signal. Connect to pin 1 of
Bosch UEGO sensor.
Pumping Current signal. Connect to pin 6
of Bosch UEGO sensor.
Trim Current signal. Connect to pin 2 of
Bosch UEGO sensor.
Lowside switch f or UEGO heater control.
Connect to pin 4 of Bosch UEGO sensor.
NOTE that pin 3 of the Sensor is heater
(+) and must be power by a f used/
switched 12V supply .
Dedicated power management CPU
Optional f ull time battery power. MUST be
powered bef ore the ignition switch input is
triggered. (See C1-65.)