16
© 2014 AEM Performance Electronics
MSD Distributor + ATI Flying Magnet + Honeywell GT101 Sensor
1. Modify and install mechanical distributor. (See Modifying Mechanical Advance Distributor, in this
document.)
2. Install ATI Flying Magnet crank trigger. (Note that an adjustable sensor mount is not provided with the
ATI crank trigger.) Position the crank sensor to be near the middle of its adjustment range while being
in between magnet targets with the engine at TDC. Set sensor air gap to .053”.
3. Wiring:
Crank Sensor – Honeywell GT-101 Sensor
Cam Sensor – Modified MSD Distributor
Note: Use shielded twisted pair wiring w/drain to ground.
Note: Use shielded wiring with drain to ground.
4. Load ATI 12 + GT101 base session and review Setup Wizard. (See Setup Wizard, in this document.)
5. Sync ignition timing. (See Syncing Ignition Timing, in this document.)