Universal 8
13
© 2014 AEM Performance Electronics
MSD Distributor + ATI AEM 24 Tooth + Honeywell GT101 Sensor
1. Modify and install mechanical advance distributor. (See Modifying Mechanical Advance Distributor, in
this document.)
2. Install ATI AEM Infinity crank trigger. (Note that an adjustable sensor mount is not provided with the
ATI crank trigger.) Position the crank sensor to be near the middle of its adjustment range while being
in between crank teeth with the engine at TDC. Set sensor air gap to .040”.
3. Wiring:
Crank Sensor – Honeywell GT-101 Sensor
Cam Sensor – Modified MSD Distributor
Note: Use shielded twisted pair wiring w/drain to ground.
Note: Use shielded wiring with drain to ground.
4. Load ATI 24 + GT101 base session and review Setup Wizard. (See Setup Wizard, in this document.)
5. Sync ignition timing. (See Syncing Ignition Timing, in this document.)